Mist Cooling System for Residential - Benefit

What is the benefit? 

  • Cooling : lower the outdoor surrounding area temperature

  • Beauty : create a visual effect and enhance the experience for viewer








High Pressure Misting Pump create a process called "Flash Evaporation". Flash evaporation removes heat in the air and evaporate the mist before anything gets wet. 

Wish to know more? Contact us at +603-7785-5369 or email yiehongm@yahoo.com or visit our Company website YIE HONG. 

Wednesday, 17 February 2016

Misting system: Mist in Fountains

Adding mist effect to a fountain or water feature simply enhances the experience for viewer.

Mist effect not only create a visual effect but it develops a more interactive experience as viewers are able to feel the presence of the fog.








Visit to our company website for more details. 




Tuesday, 19 January 2016

Best misting pump for swiftlet farm 燕子屋 最佳微雾系统



  • Dual bearing design: Lowers the head and noise by reducing friction and wear

  • Forged manifold: Anti-rust, non-leaking and design extends the life of the pump

  • Rinse cooling design: Internal rinse design channels water to packings to reduce heat stress and increase the life of the packings

  • Automatic pressure valve: Controls the consistency of the pressure, regardless of the number of nozzles used and nozzles become clogged

  • Circuit break: Stops the motor if voltage is outside of the safety parameters

  • Pressure release: Automatically releases pressure from the mist line when the pump stops to prevent leaking nozzles

  • Pressure switch: Automatically stops the pump when the water supply is interrupted, protecting the pump from damage

  • Dual filter: 0.1mm dual-mesh filter prevents debris from entering pump


Wish to know more? Contact us at +603-7785-5369 or email yiehongm@yahoo.com or visit our Company website YIE HONG. 


Wednesday, 13 January 2016

Bersedia hadapi cuaca panas? Misting System


According to the Meteorological Department of Malaysia, the current hot and dry spell in many areas in Malaysia will most probably ease off by the end of March. (Source: BHarian)

Does your farm ready to handle this hot season? 


WULI high pressure misting system allow you to perfectly control the climate in the laying house or broiler house and maximize poultry performance. WULI high pressure (1,000psi) misting system produce tiny droplets of water that evaporate in the air without wet at large area. 


Wish to know more? Visit our company website YIE HONG: WULI Misting System

Monday, 7 September 2015

Environmental dust is a health hazard

Air pollution has come under spotlight this month. Environmental dust generated from industrial process, construction and opening burning lead to severe reduction of air quality and can be a significant health hazard.

Dust suppression is a cost effective way to reduce dust levels in open or/and large area. Misting system atomize water into the air captures airborne particles of dust, leading them to the ground without getting wet.

Benefit of misting system:


  • Reduce unpleasant odors.
  • Improve air quality
  • Increase productivity with comfort working environment.
  • Save money by reducing site maintenance, clean-up costs and equipment wear. 
Wuli high pressure misting system produce micron droplets capable of capturing dust particles through this process of agglomeration. 

Find out more Wuli high pressure misting system via Yie Hong, Malaysia - Misting system




Wednesday, 19 August 2015

How to operate and maintain a mist pump?


A.     Before operation
1.     Make sure that the pump is firmly installed and the connectors are tightened properly.
2.        Before operating the motor, turn on the tap water and check whether the suction hose is connected to the pump properly. Discharge redundant air inside the pump.
3.        The volume of tap water should be at leave 10 l/min.
4.        Make sure the diameter of the suction hose is larger than 5/8 inch.
5.    Make sure the diameter of any extension cords used is larger than 2mm2.

B.      Maintenance
1.        Change the oil when the pump has been used for the first 30 ~ 50 hours.
2.        Then, change the oil after every 100 ~ 200 hours.
3.        Use #30 ~ 40~ oil, add 250cc each time.

C.     Troubleshooting
1.        Unstable working pressure
·     Check whether the suction hose is leaking, clogged or afloat.
·     Drain out the redundant air by disconnecting the outlet hose.
·     Check the valve assembly to see if it is clogged or damaged.
2.        Insufficient pressure
·   Check to see if the packing, waterproof seal and valve assembly are damaged.
·     Check to see if the pressure valve and regulating spring are worn out.
3.        Leakage
·       Check the U-packing, waterproof seal and piston. Replace them if necessary.
4.        Unusual noise
·      Check the piston and oil. Replace them if necessary.
·      Check the volume of tap water.
·      Check whether the nozzle is clogged.


Welcome to visit our website: YIE HONG SDN. BHD.












Monday, 28 April 2014

Which mist nozzle is correct?

Difference nozzle, difference output.

           Choose the output that you required and choose the correct nozzle.

Misting Pump


  • Forged Manifold: Anti-rust, non-leaking design extends the life of the pump.

  • Rinse Cooling Design: Internal rinse design channels water to packing to reduce heat stress and increase the life of the packing.

  • Dual Bearing Design: Lowers the heat and noise by reducing friction and wear.

  • Automatic Pressure Valve: Controls the consistency of the pressure, regardless of the number of nozzles used and nozzles becoming clogged.

  • Circuit Breaker: Stops the motor if the voltage is outside of the safety parameters.

Thursday, 24 April 2014

Mist cooling system installation

Installation

Misting fan:

The cooling, misting or humidification effects depend on the sizes of misting fans, nozzle sizes, spacing between nozzles and the relative humidity.

Spacing:

Standard spacing between nozzles ranges from 0.5 to 1.5 meter. Standard spacing between pipelines is determined by nozzle output and the desired humidity to be created.

Pumps and Nozzles

The choices of pumps and nozzles are determined by the size of the installation size, the requirements of cooling, misting, and humidification effects and the humidity in the air.

Pump:

The pump is determined by the number and size of nozzles used. For example, if the flow of a nozzle is 46cc/min and there are three hundred nozzles used, then the total volume of water required per minute is 13,800cc (46 x 300). Please use a pump with a minimum output volume of 13.8liters per minute. Generally, a pump with pressure more than 70kgf/cm^2 will achieve the best results.

Nozzles:

For best fogging effects, choose nozzles with small orifice sizes to reinforce cooling effects and to avoid dripping. This also helps to increase the negative ions in the air.

Maintenance

Nozzle:

Put nozzle in a container with 70c water and use mineral deposit dissolver to soak the nozzles for 4 hours; then, use an ultrasonic cleaner to clean the nozzle.


  • On-site installation
  • Adjustable nozzle angle
  • Easy maintenance
  • Durable design, resists chemicals and UV rays

Why do we need mist cooling system? 为何需要微雾降温系统?

(a) Suppress Dust 防尘



(b) Add Humidity 加湿



(c) Lower Temperatures 降温




 
(d) Neutralize Odor 除臭
 
 
 
 

Monday, 21 April 2014

Everything cool under the sun


 
  • Adjustable high up to 190cm

  • 3 speed, variable pitch oscillating fan

  • hose connector inlet with float valve shutoff

  • 38 litter tank for 2 hours of continuous misting

  • High pressure mist pump  (W.P 70bar)

  • Wheel lock for greater safety and stability

  • Motor circuit breaker for electrical safety

  • Fan can be separated from the main unit for easy handling

  • Two 10" rear wheels and one heavy duty caster for easy mobility

  • Pretty outlook

 

YIE HONG SDN BHD
 
11, JALAN 2/152,
TAMAN PERINDUSTRIAN O.U.G,
BATU 6, JALAN PUCHONG,
58200 KUALA LUMPUR.
TEL: +603-778-55369